Audio partition of the v1_0_3 Tesira design: one TesiraFORTÉ X 400, all processing on DSP 0.0. Every wire below comes from the 52 audio links decoded from the file.
Each mic feeds all four EQ presets at once: HH - 7, Lav - 7, Boundary - 7, Goose - 7. The Source Selector (WLX1Type, WLX2Type) passes one of them, chosen by logic from the Shure ULXD4D's TX_TYPE report. A Peak Meter taps both mics straight off Dante.
These four Level blocks are what the TEC-X Volume Up, Volume Down and Mute buttons drive, through the ramp Logic States Wlx1Ramp, Wlx2Ramp, MicRamp and USBRamp.
The DIAG input comes from a Diagnostics custom block: a 3-input Source Selector choosing Aux In, a Tone Generator or a Noise Generator. Crosspoint levels and on/off states are runtime settings that couldn't be read reliably from the file, so check them in the Matrix Mixer dialog.
The AEC Ref after the limiter is the far-end reference for the AEC block, so it hears exactly what the room speakers play. An RMS Meter watches this output.
An RMS Meter watches this send too.
| Stage | Block | Instance tag | Feeds |
|---|
Instance tags are the names to use for TTP and for TEC-X actions. Blocks without a custom tag keep Tesira's default name, such as Aec1 or Mixer2.